Loading...

HUB AND BUS ISOLATOR

HUB2 is a non-addressable module that extends and divides the control panel’s bus into two completely isolated bus outputs (two for each connected APR3-HUB2). It extends the combus /communication bus by regenerating the signal between the control panel and its modules. Should one bus output experience trouble or tampering, the other will remain unaffected. The hub monitors the signal between the control panel and modules on each output. If the hub detects a loss of signal integrity it will cut off the troubled output until proper communication is re-established.

  • FEATURES:
    • 1 input port, 2 isolated output ports

    • Each output port provides communication to modules at a distance of up to 900m (3000ft)

Model: HUB2


Share on :   Share on Facebook Share on Facebook
SPECIFICATIONS SPECIFICATIONS DESCRIPTION DESCRIPTION

Input Voltage

  • 12 to 16 Vdc

Current Consumption

  • Typically: 24 mA Maximum: 50 Ma

Operating Temperature

  • 0 to 55 °C (-4 to 122 °F)

Dimensions

  • 14 x 4.5 x 1.8 cm (5.5 x 1.8 x 0.7 in.)
DATA SHEET

HUB2 DATA SHEET